Also called: Autoclave, Steriliser, Sterilizer, Mesin Autoklaf
Autoclave & Medical Steriliser Supplier in Malaysia
Autoclave machines and steam sterilisers for GP clinics, dental practices, laboratories, aesthetic and tattoo studios — matched to your load, quoted in writing, delivered and installed nationwide by AA Alive.
Last updated:
- EN 13060 tabletop classes explained and quoted
- Class B, N and S
- From compact tabletop to vertical lab autoclaves
- 8–150 L
- Batu Caves, Kota Kinabalu and Kuching
- 3 branches
- Every steriliser we quote for medical instruments
- MDA-registered
Who we supply
Dental clinics
Class B autoclaves sized by chair count, for handpieces and pouched instruments.
GP and specialist clinics
Tabletop sterilisers for minor-surgery sets and dressing packs, with cycle records.
Laboratories
Vertical and benchtop lab autoclaves for media, liquids, glassware and waste.
Beauty, nail and tattoo studios
Compact autoclaves for metal tools, with honest advice on Class N vs Class B.
New clinics and renovations
Plan the dirty-to-clean reprocessing area before you choose the machine.
Existing autoclave owners
Daily, weekly and annual maintenance that keeps a steriliser passing its tests.
What an autoclave does
An autoclave is a steam steriliser: it holds instruments in saturated steam under pressure until every microorganism, including bacterial spores, is killed. “Autoclave”, “steriliser”, “sterilizer”, “steam sterilizer” and “mesin autoklaf” all describe the same machine in a clinic.
134 °C cycle
The standard fast cycle: about 2.1 bar of steam pressure and at least 3 minutes at 134 °C. Used for most wrapped and unwrapped metal instruments.
121 °C cycle
A gentler cycle of at least 15 minutes at 121 °C, used for items that tolerate heat but not 134 °C, such as some plastics, rubber and textiles.
Drying matters
A full cycle — air removal, heat-up, hold, exhaust and drying — usually takes 30 to 60 minutes. Wet packs are not considered sterile, so drying performance is worth comparing.
Read next How steam sterilisation worksMedical steriliser types compared
Types of autoclave and steriliser
Pick the type from what you reprocess, not from the price tag.
| Type | Best for | What it can process | Typical size |
|---|---|---|---|
| Class B tabletop autoclave | Dental, GP, aesthetic, surgical | Wrapped, porous and hollow loads (handpieces, cannulae) | 17–23 L |
| Class N tabletop autoclave | Simple clinics, beauty and tattoo studios | Unwrapped solid instruments only | 8–18 L |
| Class S tabletop autoclave | Mixed loads named by the manufacturer | Whatever the maker has validated it for | 12–23 L |
| Vertical (top-loading) autoclave | Laboratories, universities, factories | Media, liquids, glassware, waste | 35–150 L |
| Dry-heat (hot-air) steriliser | Heat-stable metal and glass | Items that must stay dry | Small cabinets |
| Low-temperature (EO / plasma) | Hospital CSSD | Heat-sensitive devices | Floor-standing |
Read next Autoclave machine sizesLaboratory autoclavesDental autoclaves
Class B, N and S — which one you need
European standard EN 13060 sorts small steam sterilisers (chambers up to 60 litres) into three classes by the loads they are proven to sterilise.
Class B
Uses a fractionated pre-vacuum to pull air out of hollow and porous items, so steam reaches inside handpieces, lumens and wrapped packs. If you sterilise anything wrapped or hollow, you need Class B.
Class N
Removes air passively. Only proven for unwrapped, solid instruments that are used immediately. Cheaper, but not suitable for pouched instruments you store.
Class S
Validated by the manufacturer for specific load types between N and B. Read exactly which loads are covered before buying.
Read next Class B vs N vs S in depth
How to choose an autoclave for your clinic
- Count your instruments per day and per batch — chamber volume (litres) and tray count must cover your peak session, not your average.
- List what is hollow or wrapped. Dental handpieces, suction tips and pouched kits all need a Class B cycle.
- Check the water system: most units need distilled or deionised water; some accept a water purifier connection.
- Ask for cycle times with drying for a full load, not the fastest empty-chamber figure.
- Ask how cycles are recorded — printer, USB or data logger — because you will need records for audits.
- Confirm power and bench space. Large tabletop units can draw over 2 kW and need clearance for ventilation.
- Ask who services it, how fast, and the price of door seals, filters and annual calibration.
- Ask for the MDA registration number for a steriliser sold for medical instruments.
Read next What drives autoclave pricePlan your sterilisation room
Proving every load is sterile
Physical
Time, temperature and pressure for every cycle, printed or logged. This is your first line of evidence.
Chemical
Indicator tape and pouch indicators only show a pack went through a cycle. Integrator strips (ISO 11140-1 types 5 and 6) inside packs check time, temperature and steam together.
Air-removal test
Vacuum (Class B) sterilisers are checked with a Bowie-Dick or helix test, typically at the start of each day.
Biological
Spore tests with Geobacillus stearothermophilus are the definitive check, commonly run weekly and after repairs. Follow your facility’s infection-control policy.
MDA registration and your steriliser
Under the Medical Device Act 2012 (Act 737), a medical device must be registered with the Medical Device Authority (MDA) before it is imported, exported or placed on the Malaysian market. A steriliser sold for reprocessing medical instruments is itself a medical device, so ask for its MDA registration number and check it on the MDA’s public register before you pay.
How we quote
- You tell us your practice type, daily instrument count, what is hollow or wrapped, and your location.
- We shortlist suitable classes and chamber sizes and explain the trade-offs.
- You get a written quotation listing the unit, delivery, installation, training, warranty and consumables separately.
- After installation we can help with your first Bowie-Dick and spore tests and set up cycle records.
How to buy an autoclave in five steps
The order we work through with every clinic and lab, so the machine fits the load rather than the brochure.
Count your load
List the instruments you reprocess in your busiest session, and which are hollow, porous or pouched.
Choose the class
Wrapped or hollow loads need Class B; unwrapped solid instruments used at once can use Class N.
Size the chamber
Match chamber litres and tray count to the peak session, with room for steam to circulate.
Compare written quotes
Compare like for like: class, volume, warranty, records, installation, service and MDA registration.
Install, test and record
Install, run the first Bowie-Dick and spore tests with your staff and set up cycle records.
Buyer’s guides
Autoclave & Steriliser Supplier in your city
We quote, deliver and install across Peninsular Malaysia from our Batu Caves headquarters, and across Sabah and Sarawak from our Kota Kinabalu and Kuching branches.
- Autoclave Kuala LumpurKuala Lumpur
- Autoclave SelangorSelangor
- Autoclave Petaling JayaSelangor
- Autoclave Shah AlamSelangor
- Autoclave KlangSelangor
- Autoclave SerembanNegeri Sembilan
- Autoclave MelakaMelaka
- Autoclave Johor BahruJohor
- Autoclave IpohPerak
- Autoclave PenangPulau Pinang
- Autoclave Alor SetarKedah
- Autoclave Kota BharuKelantan
- Autoclave Kuala TerengganuTerengganu
- Autoclave KuantanPahang
- Autoclave Kota KinabaluSabah
- Autoclave KuchingSarawak
Key terms explained
- Autoclave
- A steriliser that uses saturated steam under pressure to kill all microorganisms, including spores.
- Air removal
- Getting air out of the chamber and load so steam can touch every surface — by vacuum pulses or steam displacement.
- Biological indicator
- A test containing resistant bacterial spores (Geobacillus stearothermophilus) that shows whether a cycle actually killed them.
- Bowie-Dick test
- A daily test pack for vacuum sterilisers that shows whether air removal and steam penetration are working.
- Chemical indicator
- A strip or ink that changes colour when exposed to sterilising conditions; types 1–6 under ISO 11140-1 differ in how much they prove.
- Class B
- EN 13060 class for small sterilisers proven on wrapped, porous and hollow loads, using fractionated pre-vacuum.
- Class N
- EN 13060 class proven only for unwrapped solid instruments, using passive air removal.
- Class S
- EN 13060 class for the specific load types the manufacturer has validated.
Frequently asked questions
What is the difference between an autoclave and a steriliser?
Which autoclave do dental clinics need?
What size autoclave should a GP clinic buy?
How long does an autoclave cycle take?
Is a UV steriliser cabinet enough for clinic instruments?
What water should I use in an autoclave?
Do autoclaves need to be registered in Malaysia?
Do you publish autoclave prices?
Get a written quotation
Tell us your clinic or lab type, daily workload and location. We match suitable models and send a written quotation with delivery, installation and training spelled out.